Package CIM15 :: Package IEC61970 :: Package Domain
[hide private]
[frames] | no frames]

Package Domain

The domain package define primitive datatypes that are used by classes in other packages. Stereotypes are used to describe the datatypes. The following sterotypes are defined <<enumeration>> A list of permissable constant values. <<Primitive>> The most basic data types that all other data types derive from. <<CIMDataType>> A datatype that contains a value attribute, an optional unit of measure and a unit multiplier. The unit and multiplier are specified as a static variable initialized to the allowed value. <<Compound>> A composite of two or more attributes.

Submodules [hide private]

Classes [hide private]
  UnitSymbol
Values are: N, A, rad, VAh, Pa, J, h, Hz, VArh, ohm, H, m3, deg, V, oC, F, Wh, s, g, min, S, none, W, VAr, m2, m, VA
  Currency
Values are: CAD, EUR, CHF, INR, AUD, USD, RUR, GBP, CNY, SEK, JPY, other, NOK, DKK
  UnitMultiplier
Values are: M, G, d, micro, c, p, n, T, k, m, none
  ReactancePerLength
Reactance (imaginary part of impedance) per unit of length, at rated frequency.
  ApparentPower
Product of the RMS value of the voltage and the RMS value of the current
  Damping
Per-unit active power variation with per-unit frequency referenced on the system apparent power base.
  Susceptance
Imaginary part of admittance.
  ResistancePerLength
Resistance (real part of impedance) per unit of length.
  PU
Per Unit - a positive or negative value referred to a defined base.
  CurrentFlow
Electrical current (positive flow is out of the ConductingEquipment into the ConnectivityNode)
  AngleDegrees
Measurement of angle in degrees
  CostRate
Cost, in units of currency, per hour of elapsed time
  CostPerEnergyUnit
Cost, in units of currency, per quantity of electrical energy generated.
  Displacement
Unit of displacement relative a reference position, hence can be negative.
  Voltage
Electrical voltage.
  Reactance
Reactance (imaginary part of impedance), at rated frequency.
  Pressure
Pressure in Pascal.
  Temperature
Value of temperature in degrees Celsius.
  RotationSpeed
Number of revolutions per second.
  SusceptancePerLength
Imaginary part of admittance per unit of length.
  StringQuantity
Quantity with string value (when it is not important whether it is an integral or a floating point number) and associated unit information.
  ActivePowerChangeRate
  AbsoluteDate
Date and time as 'yyyy-mm-dd', which conforms with ISO 8601.
  ActivePower
Product of RMS value of the voltage and the RMS value of the in-phase component of the current
  Volume
Volume.
  Conductance
Factor by which voltage must be multiplied to give corresponding power lost from a circuit.
  Inductance
Inductance.
  ReactivePower
Product of RMS value of the voltage and the RMS value of the quadrature component of the current.
  AngleRadians
Phase angle in radians
  Frequency
Cycles per second
  Capacitance
A Farad, the typical unit, is the capacitance in which a charge of 1 coulomb produces 1 volt potential difference between its terminals.
  Money
Amount of money
  RealEnergy
Real electrical energy
  KWActivePower
Active power in kilowatts.
  Minutes
Time in minutes
  Impedance
Ratio of voltage to current.
  VoltagePerReactivePower
Voltage variation with reactive power
  VolumeFlowRate
  ConductancePerLength
Real part of admittance per unit of length.
  PerCent
Normally 0 - 100 on a defined base
  Weight
The weight of an object.
  Resistance
Resistance (real part of impedance).
  Seconds
Time, in seconds
  FloatQuantity
Quantity with float value and associated unit information.
  WaterLevel
Reservoir water level referred to a given datum such as mean sea level.
  Length
Unit of length.
  Hours
Time, in hours
  IntegerQuantity
Quantity with integer value and associated unit information.
  CostPerVolume
Variables [hide private]
  nsURI = 'http://iec.ch/TC57/2010/CIM-schema-cim15#Domain'
  nsPrefix = 'cimDomain'