Package CIM14 :: Package CDPSM :: Package GIS_Connectivity :: Package IEC61970 :: Package Wires :: Module BusbarSection' :: Class BusbarSection
[hide private]
[frames] | no frames]

Class BusbarSection

                           object --+                    
                                    |                    
                     Element'.Element --+                
                                        |                
  Core.IdentifiedObject'.IdentifiedObject --+            
                                            |            
Core.PowerSystemResource'.PowerSystemResource --+        
                                                |        
                        Core.Equipment'.Equipment --+    
                                                    |    
        Core.ConductingEquipment'.ConductingEquipment --+
                                                        |
                                                       BusbarSection

A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation. Voltage measurements are typically obtained from VoltageTransformers that are connected to busbar sections. A bus bar section may have many physical terminals but for analysis is modelled with exactly one logical terminal.

Instance Methods [hide private]
 
__init__(self, *args, **kw_args)
Initialises a new 'BusbarSection' instance.

Inherited from Core.ConductingEquipment'.ConductingEquipment: addTerminals, getBaseVoltage, getTerminals, removeTerminals, setBaseVoltage, setTerminals

Inherited from Core.Equipment'.Equipment: getEquipmentContainer, setEquipmentContainer

Inherited from Core.PowerSystemResource'.PowerSystemResource: getGeoLocation, getPSRType, setGeoLocation, setPSRType

Inherited from object: __delattr__, __format__, __getattribute__, __hash__, __new__, __reduce__, __reduce_ex__, __repr__, __setattr__, __sizeof__, __str__, __subclasshook__

Class Variables [hide private]
  _attr_types = {}
  _attrs = []
  _defaults = {}
  _enums = {}
  _many_refs = []
  _refs = []
Properties [hide private]

Inherited from Core.ConductingEquipment'.ConductingEquipment: BaseVoltage, Terminals

Inherited from Core.Equipment'.Equipment: EquipmentContainer

Inherited from Core.PowerSystemResource'.PowerSystemResource: GeoLocation, PSRType

Inherited from object: __class__

Method Details [hide private]

__init__(self, *args, **kw_args)
(Constructor)

 

Initialises a new 'BusbarSection' instance.

Parameters:
  • phases - Describes the phases carried by a conducting equipment. Values are: "ABC", "splitSecondary2N", "ABN", "CN", "ACN", "BC", "AN", "BN", "AB", "splitSecondary1N", "N", "C", "AC", "ABCN", "splitSecondary12N", "A", "B", "BCN"
  • Terminals - ConductingEquipment has 1 or 2 terminals that may be connected to other ConductingEquipment terminals via ConnectivityNodes
  • BaseVoltage - Use association to ConductingEquipment only when there is no VoltageLevel container used.
Overrides: object.__init__