Package CIM14 :: Package CDPSM :: Package Balanced :: Package IEC61970 :: Package Wires :: Module ShuntCompensator' :: Class ShuntCompensator
[hide private]
[frames] | no frames]

Class ShuntCompensator

                           object --+                    
                                    |                    
                     Element'.Element --+                
                                        |                
  Core.IdentifiedObject'.IdentifiedObject --+            
                                            |            
Core.PowerSystemResource'.PowerSystemResource --+        
                                                |        
                        Core.Equipment'.Equipment --+    
                                                    |    
        Core.ConductingEquipment'.ConductingEquipment --+
                                                        |
                                                       ShuntCompensator

A shunt capacitor or reactor or switchable bank of shunt capacitors or reactors. A section of a shunt compensator is an individual capacitor or reactor. A negative value for reactivePerSection indicates that the compensator is a reactor. ShuntCompensator is a single terminal device. Ground is implied.

Instance Methods [hide private]
 
__init__(self, nomQ=0.0, nomU=0.0, normalSections=0, maximumSections=0, reactivePerSection=0.0, *args, **kw_args)
Initialises a new 'ShuntCompensator' instance.

Inherited from Core.ConductingEquipment'.ConductingEquipment: addTerminals, getBaseVoltage, getTerminals, removeTerminals, setBaseVoltage, setTerminals

Inherited from Core.Equipment'.Equipment: getEquipmentContainer, setEquipmentContainer

Inherited from Core.PowerSystemResource'.PowerSystemResource: getGeoLocation, getPSRType, setGeoLocation, setPSRType

Inherited from object: __delattr__, __format__, __getattribute__, __hash__, __new__, __reduce__, __reduce_ex__, __repr__, __setattr__, __sizeof__, __str__, __subclasshook__

Class Variables [hide private]
  _attr_types = {'maximumSections': <type 'int'>, 'nomQ': <type ...
  _attrs = ['nomQ', 'nomU', 'normalSections', 'maximumSections',...
  _defaults = {'maximumSections': 0, 'nomQ': 0.0, 'nomU': 0.0, '...
  _enums = {}
  _many_refs = []
  _refs = []
Properties [hide private]

Inherited from Core.ConductingEquipment'.ConductingEquipment: BaseVoltage, Terminals

Inherited from Core.Equipment'.Equipment: EquipmentContainer

Inherited from Core.PowerSystemResource'.PowerSystemResource: GeoLocation, PSRType

Inherited from object: __class__

Method Details [hide private]

__init__(self, nomQ=0.0, nomU=0.0, normalSections=0, maximumSections=0, reactivePerSection=0.0, *args, **kw_args)
(Constructor)

 

Initialises a new 'ShuntCompensator' instance.

Parameters:
  • nomQ - Nominal reactive power output of the capacitor bank at the nominal voltage. This number should be positive.
  • nomU - The nominal voltage at which the nominal reactive power was measured. This should normally be within 10% of the voltage at which the capacitor is connected to the network.
  • normalSections - For a capacitor bank, the normal number of sections switched in. This number should correspond to the nominal reactive power (nomQ).
  • maximumSections - For a capacitor bank, the maximum number of sections that may be switched in.
  • reactivePerSection - For a capacitor bank, the size in reactive power of each switchable section at the nominal voltage.
Overrides: object.__init__

Class Variable Details [hide private]

_attr_types

Value:
{'maximumSections': <type 'int'>,
 'nomQ': <type 'float'>,
 'nomU': <type 'float'>,
 'normalSections': <type 'int'>,
 'reactivePerSection': <type 'float'>}

_attrs

Value:
['nomQ',
 'nomU',
 'normalSections',
 'maximumSections',
 'reactivePerSection']

_defaults

Value:
{'maximumSections': 0,
 'nomQ': 0.0,
 'nomU': 0.0,
 'normalSections': 0,